Configuring Ethernet Ports Combo Port Application Example
OmniSwitch 6800/6850/9000 Network Configuration Guide June 2006 page 1-25
3 Verify that combo ports 1/47 and 1/48 are set to the default setting of preferred fiber (which will make
the MiniGBIC SFP ports 1/47 and 1/48 the primary connections while copper combo ports 1/47 and 1/48
will only become active if the equivalent MiniGBIC SFP ports go down) with the show interfaces status
command as shown below:
-> show interfaces 1/45-48 status
DETECTED CONFIGURED
Slot/ AutoNego Speed Duplex Hybrid Speed Duplex Hybrid Trap
Port (Mbps) Type (Mbps) Mode LinkUpDown
-----+--------+------+------+------+--------+------+------+------
1/45 Enable - - - 100 Auto FC -
1/45 Enable - - - 1000 Full FC -
1/46 Enable - - - 100 Auto FC -
1/46 Enable - - - 1000 Full FC -
1/47 Enable - - - 1000 Full PF -
1/47 Enable - - - 100 Auto PF -
1/48 Enable - - - 1000 Full PF -
1/48 Enable - - - 100 Auto PF -
FF - ForcedFiber PF - PreferredFiber F - Fiber
FC - ForcedCopper PC - PreferredCopper C - Copper
In the output above combo ports 1/47 and 1/48 are set to preferred fiber. (To configure combo ports as
preferred fiber use the interfaces hybrid preferred-fiber command.)