Configuring Ethernet Ports Ethernet Ports Overview
OmniSwitch 6800/6850/9000 Network Configuration Guide June 2006 page 1-7
Autonegotiation Guidelines
Please note a link will not be established on any copper Ethernet port if any one of the following is true:
• The local port advertises 100 Mbps full duplex and the remote link partner is forced to 100 Mbps full
duplex.
• The local port advertises 100 Mbps full duplex and the remote link partner is forced to 100 Mbps half
duplex.
• The local port advertises 10 Mbps full duplex and the remote link partner is forced to 10 Mbps full
duplex.
• The local port advertises 10 Mbps full duplex and the remote link partner is forced to 10 half duplex.
This is due to the fact that when the local device is set to auto negotiating 10/100 full duplex it senses the
remote device is not auto negotiating. Therefore it resolves to Parallel Detect with Highest Common
Denominator (HCD), which is “10/100 Half” according to IEEE 802.3 Clause 28.2.3.1.
However, since the local device is set to auto negotiating at 10/100 full duplex it cannot form a 10/100
Mbps half duplex link in any of the above mentioned cases. One solution is to configure the local device
to autonegotiation, 10/100 Mbps, with auto or half duplex.