There is no hardware configuration for IBS other than selecting between an external power
supply for each IBS and remote power by system.
To configure the IBS software:
ARI Number
The ARI number identifies each OmniPCX Office. Each OmniPCX Office has an identical
default ARI number.
When you install a new OmniPCX Office, you have to change the default ARI number. You
can only keep the first digit, which is "1" and which means "ARI type B".
- 1 In OMC, go to System Miscellaneous -->DECT/PWT ARI/GAP
- 2 Enter your own number (octal digit) to register your DECT handset.
___change-begin___
___change-end___
Figure 4.60: ARI Number
Note 1:
The ARI Number is the only non plug and play device on the IBS.
The default configuration fits with the major systems. Modifications should answer to specific needs.
Line length
The Line length is the cable length used to plug the IBS to the system (distance between the
IBS and OmniPCX Office). It enables the system to add a delay in signal and to avoid a shift in
clock signal that creates a reset of the IBS.
- 1 In OMC, go to Users/Base stations List.
- 2 Select the IBS Master and click Details
  *+
     
4-69